DLO Cable (Diesel Locomotive)
600 to 2000 Volts - 90°C
UL RHH/RHW.CSA R90 |
 |
No Cut Charge
Same Day Shipments
|
DLO Cable from Delco Wire is especially suitable to supply power to traction motors of diesel-electric locomotives. It is also recommended as a portable cable for drilling rigs, on-shore or off-shore, railroad and transit car wiring, electric earth-moving equipment, in shipyard applications, arc welder supply leads, power and control jumper cable, case wire and motor leads. This cable is suitable for use in wet or dry areas, conduits, ducts, troughs or tray, and where superior electrical properties are desired. The maximum continuous conductor temperature for normal operation in wet or dry locations is 90 °C (194 °F).
Construction |
Conductor: |
- |
|
Insulation: |
- |
Premium Grade 90°C EPDM or EPR/HYP 2KV |
Separator: |
- |
Suitable separator is applied between the conductor and insulation for easy stripping. |
Jacket: |
- |
Heavy Duty Thermoset or CSPE |
Applications: |
- |
Diesel electric locomotives, oil and gas drilling rigs, general shipyard use, mining and earth moving equipment.
Generally use at voltages up to 2kV where flexibility and portability are required.
Excellent for use in heavy flexing applications as a motor or apparatus lead. |
Standards |
- |
UL Listed and Non UL Listed Available
1/0 AWG and higher - CT Rated
OSHA Acceptable and MSHA Approved |
8 AWG - Stranding Bare Copper (37) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
774 |
.045" |
.030" |
.330" |
83 |
90 |
|
6 AWG - Stranding Bare Copper (61) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
775 |
.060" |
.030" |
.410" |
109 |
140 |
|
4 AWG - Stranding Bare Copper (105) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
777 |
.060" |
.030" |
.460" |
145 |
200 |
|
2 AWG - Stranding Bare Copper (154) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
779 |
.060" |
.030" |
.520" |
192 |
290 |
|
1 AWG - Stranding Bare Copper (224) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
780 |
.080" |
.045" |
.649" |
223 |
450 |
|
1/0 AWG - Stranding Bare Copper (280) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
781 |
.080" |
.045" |
.680" |
258 |
520 |
|
2/0 AWG - Stranding Bare Copper (329) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
782 |
.080" |
.045" |
.718" |
298 |
590 |
|
3/0 AWG - Stranding Bare Copper (456) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
783 |
.080" |
.045" |
.810" |
345 |
780 |
|
4/0 AWG - Stranding Bare Copper (551) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
784 |
.080" |
.045" |
.838" |
400 |
980 |
|
262.6 AWG - Stranding Bare Copper (650) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
785 |
.095" |
.065" |
.955" |
458 |
1130 |
|
313.1 AWG - Stranding Bare Copper (775) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
786 |
.095" |
.065" |
1.04" |
514 |
1300 |
|
373.3 AWG - Stranding Bare Copper (925) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
787 |
.095" |
.065" |
1.15" |
574 |
1570 |
|
444.4 AWG - Stranding Bare Copper (1100) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
788 |
.095" |
.065" |
1.25" |
642 |
1850 |
|
535 AWG - Stranding Bare Copper (1313) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
789 |
.110" |
.065" |
1.305" |
725 |
2110 |
|
777.7 AWG - Stranding Bare Copper (1925) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
791 |
.120" |
.065" |
1.55" |
910 |
3050 |
|
929.2 AWG - Stranding Bare Copper (2318) - Get Quote
| P/N |
Nom. Insulation
Thickness (Inches) |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
793 |
.120" |
.065" |
1.65" |
1025 |
3725 |
|
Back to Top |
|