Stage Lighting Cable
105°C - 600 Volt |
 |
No Cut Charge
Same Day Shipments
|
Stage Lighting Cable from Delco Wire & Cable (Type SC Stage Lighting and Power cables) also known as entertainment cables exceed both UL and CSA performance requirements. These cables are tough, light weight and extremely flexible. These cables have a smaller overall diameter than previous available cables and offer outstanding abuse resistance for demanding stage lighting and entertaining industry applications. This cable is ideal for portable power and lighting applications in the entertainment industry including motion picture, television, theatres, stages and outdoor events.
Construction |
Conductor: |
- |
|
Separator: |
- |
Polyester tape |
Jacket: |
- |
Special heavy duty, EP/CP Jacket, Oil resistant and flame retardant. |
Applications: |
- |
Portable power systems
Entertainment industry activities such as; theatre, television, night clubs, motion pictures, mobile communication vans, spotlights and sounds systems.
Other similar applications that would require temporary power. |
Features: |
- |
Water resistant
Sunlight resistant
Designed to withstand severe environmental conditions.
Withstands exposure to oil, acids, alkalis, heat, flame, moisture and chemicals.
Meets or exceeds flame test requirements of MSHA, CSA and UL. |
Industry Approvals: |
- |
|
6 AWG - Stranding Bare Copper (259) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
75606 |
.070" |
.333" |
105 |
118 |
|
4 AWG - Stranding Bare Copper (418) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
75604 |
.070" |
.387" |
140 |
175 |
|
2 AWG - Stranding Bare Copper (660) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
75602 |
.070" |
.458" |
190 |
260 |
|
1 AWG - Stranding Bare Copper (836) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
75601 |
.090" |
.543" |
220 |
342 |
|
1/0 AWG - Stranding Bare Copper (1056) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
75610 |
.090" |
.575" |
260 |
416 |
|
2/0 AWG - Stranding Bare Copper (1320) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
75620 |
.090" |
.626" |
230 |
508 |
|
3/0 AWG - Stranding Bare Copper (1672) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
75630 |
.090" |
.678" |
350 |
627 |
|
4/0 AWG - Stranding Bare Copper (2090) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
75640 |
.090" |
.741" |
405 |
768 |
|
Back to Top |
|