Type W Single Conductor Cable
90°C - 600 to 2000 Volt - UL |
 |
No Cut Charge
Same Day Shipments
|
Type W Single Conductor Cable is recommended when long life and flexibility are desired. PowerHouse Cable stocks a variety of Type W-cables including the premier Anaconda® Brand lead-cured mining cables and Carol® Brand CV-cured industrial-grade power cables for mining applications. Delco Wire & Cable is the one source for the industry's most comprehensive range of cable constructions and engineered solutions.
8 AWG - Stranding Bare Copper (168) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
71108 |
.060" |
.440" |
155 |
80 |
|
6 AWG - Stranding Bare Copper (266) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
71106 |
.060" |
.535" |
267 |
105 |
|
4 AWG - Stranding Bare Copper (420) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
71104 |
.060" |
.600" |
369 |
140 |
|
2 AWG - Stranding Bare Copper (651) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
71102 |
.060" |
.630" |
190 |
458 |
|
1 AWG - Stranding Bare Copper (259) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
71101 |
.080" |
.745" |
475 |
223 |
|
1/0 AWG - Stranding Bare Copper (1064) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
71110 |
.080" |
.775" |
658 |
260 |
|
2/0 AWG - Stranding Bare Copper (1311) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
71120 |
.080" |
.815" |
730 |
300 |
|
3/0 AWG - Stranding Bare Copper (259) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
71130 |
.080" |
.910" |
345 |
805 |
|
4/0 AWG - Stranding Bare Copper (2090) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
71140 |
.080" |
.930" |
405 |
1049 |
|
250 AWG - Stranding Bare Copper (629) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
711250 |
.095" |
1.08" |
455 |
1425 |
|
350 AWG - Stranding Bare Copper (888) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
711350 |
.095" |
1.20" |
570 |
1971 |
|
500 AWG - Stranding Bare Copper (1221) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
711500 |
.095" |
1.34" |
700 |
2651 |
|
750 AWG - Stranding Bare Copper (427) - Get Quote
| P/N |
Nom. Jacket
Thickness (Inches) |
Nom. O.D. (inches) |
Allowable Ampacity |
Lbs. / M' |
711750 |
.110" |
1.56" |
805 |
3305 |
|
Back to Top |
|